Features

Technical Data

Load Forward voltage Output current Max. output power (at 24 V, full load) Typ. power con­sump­tion (at 24 V, full load) Typ. current consumption (at 24 V, full load) tc point max. Ambient temperature ta
10% 24 V 0.625 A 15 W 19.1 W 122 mA 80 °C -25 ... +60 °C
20% 24 V 1.250 A 30 W 34.3 W 174 mA 80 °C -25 ... +60 °C
30% 24 V 1.875 A 45 W 49.7 W 235 mA 80 °C -25 ... +60 °C
40% 24 V 2.500 A 60 W 65.2 W 298 mA 85 °C -25 ... +55 °C
50% 24 V 3.125 A 75 W 80.7 W 364 mA 85 °C -25 ... +55 °C
60% 24 V 3.750 A 90 W 96.3 W 430 mA 85 °C -25 ... +55 °C
70% 24 V 4.375 A 105 W 112.1 W 498 mA 90 °C -25 ... +50 °C
80% 24 V 5.000 A 120 W 127.7 W 565 mA 90 °C -25 ... +50 °C
90% 24 V 5.625 A 135 W 143.3 W 633 mA 90 °C -25 ... +50 °C
100% 24 V 6.250 A 150 W 159.3 W 702 mA 90 °C -25 ... +50 °C